This unit features single or dual compressor(s) and a vertical discharge air-cooled condenser that is suitable for large walk-in coolers and freezers, blast freezers, warehouse applications and air conditioned spaces where roof mounted condensers are most practical.

Using high efficiency compressors and utilizing the THERMOSPAN™ condenser core design, the unit meets all application needs from 15 to 100 Hp (high and medium temperature) and 10 to 80 Hp (low temperature).

• Units are CULUS Listed.

• Designed for use with R22, R404A and R507.

• Energy efficient compressors with POE or mineral oil.

• Several compressor options to choose from: Copeland and Bitzer

• Single, Dual and parallel-piped (optional) compressor configurations available.

• ThermospanTM condenser core design eliminates tube sheet leaks and provides reliable operation.

• 3/8″ condenser tubes reduces refrigerant charge.

• Generously sized condenser allows unit to operate at higher than normal ambient conditions.

• Optional coating and fin surfaces for condenser core protection available.

• Specially designed, thermally protected and permanently lubricated ball bearing condenser fan motor(s).

• Receivers (where used) are liberally sized and include inlet as well as outlet service valves.

• Subcooling circuit in condenser on all models (except air conditioning and H2 models) increases overall system efficiency and provides dependable compressor operation.

• Utilizes pre-formed internal piping, eliminates welded joints and reduces chances of a leak.

• Electrical components are housed in a spacious and conveniently located panel.

In case of a compressor trip, (except on air conditioning models) a lock-out relay de-energizes the liquid line solenoid valve. In addition, SPDT contact is provided for field wired alarm circuit.

• End compartment panels allow unrestricted access to service the compressor(s) and all other components.

• Raceway for pressure control wiring and connections provides neat appearance.

• Units are available with energy efficient ThermosaverTM hot gas defrost option.

• Units are environmentally friendly operating on less power and refrigerant charge.

 

Refrigeration standard features include:

• Spring mount compressor with discharge vibration eliminator.

• Compressor head cooling fans on low temperature models

• Compressor crankcase heater

• Flexible hose on all compressor pressure control connections

• Two valve adjustable (pre-set at factory) low ambient head pressure control.

• Condenser fan cycling control (pressure) on two-fan models and up.

• Fused condenser fan motors

• Receiver inlet/outlet valves and safety pressure relief valve

• Replaceable liquid line drier & sight glass

• Anti-short cycle time delay relay

• Oil failure control (non-electronic)

• Discharge line thermostat

• Separate HP and LP compressor controls.

• Part-winding start on all 30 HP and up, operating on 208/230V-3Ph.

• Lock out relay.

• Sub-cooling circuit on medium and low temperature units.

Optional Features (Factory Mounted):
• Suction line vibration eliminator

• Suction accumulator (with or without heat exchanger)

• Replaceable suction filter

• Insulated suction lines.

• Crankcase Pressure Regulating valve

• Compressor capacity control (cylinder unloading on 4D-6D-6F compressors or ModuloadTM on 3D compressor)

• Discharge line check valve

• Hot gas bypass tees / regulating valves / de-superheating TXV

• Oil separator

• Oversized condenser

• Oversized receiver

• Heated and insulated receiver

• ThermosaverTM defrost.

• Disconnect switch (fused or non-fused).

• Compressor circuit breaker

• Electronic Oil failure control

• Voltage / Phase monitor

• Part-winding start (standard on 30HP and up operating on 208/230-3)

• Defrost Time clock

• Defrost Heater / Evaporator Fan Contactors with fuse block

• Single point electrical service hook up for evaporator and controls

  • High, medium and low temperature applications.
  • Dual or Single Compressor

  • Nominal Capacities from 10 to 100 Tons for high, medium and low temperature applications

  • 208-230/3/60
  • 460/3/60
  • 575/3/60
  • 200-220/3/50
  • 380-400/3/50