TRENTON TEZ – Indoor/Outdoor Air Cooled Scroll Condensing Units
Models range in capacity from 1 HP to 15 HP for high, medium and low temperature applications.
The EZ units are available with Copeland or Tecumseh scroll compressors and come complete with many standard features. In addition to the numerous options available and following the convention of our other “E” product lines, there are nine factory-installed option packages pre-selected for your convenience.
Indoor Unit:
• Weatherproof electrical control box with compressor contactor and fused control circuit
• Welded hermetic scroll compressor
• High efficiency enhanced tube and fin condenser design
• Energy efficient PSC condenser fan motor
• Receiver with fusible plug and liquid shut off valve
• Suction service valve
• Pre-formed copper tubing
• Liquid injection (low temp. models)
• Unit leak tested and shipped with Helium holding charge
• Fixed high and adjustable low pressure control
• Receiver inlet and outlet shut off valve (2 fan units)
• Discharge thermostat (Copeland models only) on applicable models only
Outdoor Unit: All Standard Features of Indoor Unit, Plus:
• Outdoor weather-resistant housing with removable hood
• Flooded head pressure control (non adjustable)
• Crankcase heater
• Fan cycling control with flex hose (2 fan units)
Nine pre-selected factory-installed option packages available
Optional Features (Factory Mounted):
• Suction accumulator
• Suction accumulator with boil-out coil
• Discharge line Check valve
• Oil separator
• Oil separator c/w oil return filter & solenoid valve
• Adjustable head pressure control valves
• Receiver inlet ball valve
• Heated and Insulated receiver
• Over-sized receiver
• Sealed liquid line filter drier & sight-glass
• Ball valve – liquid line (shipped loose)
• Insulated suction lines
• Leg Kits
• Discharge air hood
• Sub cooling circuit on 5 – 15 HP models
• Liquid line solenoid valve-(with standard 230 volt coil)-shipped loose
• Adjustable low pressure control with flex hose
• Compressor Circuit breaker
• Current sensing relay – for use with Oil safety control (where applicable)
• Defrost heater contactor c/w fuse block
• Evaporator Fan contactor c/w fuse block
• Disconnect switch
• Disconnect Fusing
• Pump down toggle switch
• Lock out control circuit relay
• Hoffmann Speed control for condenser fan (replaces flooded valve)
• Time delay relay for compressor
• Mechanical Time Clock
• Electronic Defrost Kit
• Electronic Voltage/Phase Monitor
- High, Medium and Low Temperature Refrigeration applications.
- Indoor or Outdoor
- 1 HP to 15 HP for high, medium and low temperature applications.
- 208-230/1/60
- 208-230/3/60
- 460/3/60
- 575/3/60
- 220/1/50
- 200-220/3/50
- 380-400/3/50